A compliance test for emergency lighting is what it sounds like.

An Emergency Lighting Test is a formal inspection and verification process designed to ensure that emergency lighting systems in a building are fully operational, properly maintained, and compliant with UK safety regulations, including BS 5266-1:2016. This test is a legal requirement for landlords, property managers, and building owners in both commercial and residential properties.

graphic05 free img

What does the test involve?

  • Simulating a Power Failure: Engineers simulate a mains power outage to test the response of emergency lighting systems.
  • Fixture Evaluation: Each light is checked for:
    • Prompt activation.
    • Minimum illumination duration.
    • Proper positioning in stairways, corridors, and critical areas.
  • System Inspection: Backup batteries, control switches, and wiring integrity are assessed to rule out faults.
  • Documentation: Results are logged for compliance and audit purposes.
  •  
graphic05 free img

Why is it important?

Neglecting regular emergency lighting tests can lead to:

  • Hefty fines for non-compliance.
  • Voided insurance policies.
  • Endangered lives during emergencies.

By engaging certified professionals, landlords and property managers can ensure their systems are compliant, reliable, and ready to protect lives during unexpected outages.

graphic05 free img

Emergency lighting standards

The BS 5266-1:2016 standard governs emergency lighting in the UK, providing detailed guidelines for:

  • Installation: Proper placement of lights in critical areas.
  • Testing Frequency: Monthly functional tests and annual full-duration discharge tests.
  • Maintenance Protocols: Regular inspections to ensure system integrity.

Key Requirements:

  • Monthly Tests: Short-duration functional tests to verify activation.
  • Annual Tests: Full-duration discharge tests to ensure lights remain illuminated for the required time.

Failure to comply with these standards can result in legal penalties, insurance issues, and safety risks.

Electrical Safety in London
Electrical Installation Certificate

Our qualified electricians deliver precise Electrical Installation Condition Reports (EICR) to guarantee your property’s electrical safety.

Design of the Week

Rubber Print Your T-Shirt
Electrical Engineer in London
Electrician in London

New T-shirt Edition

Customize Plain Colors

Our Pricing

  • We offer transparent and cost-effective pricing to help you stay compliant without hidden fees:

    • Up to 3 Emergency Lights: £69
    • Each Additional Light: £15
    • Parking (if applicable): £5
    • Congestion Zone (if applicable): £15
    Our pricing ensures full compliance with emergency lighting test regulations while keeping costs manageable.
graphic05 free img

Emergency Lighting: Testing & Types

How to Test Emergency Lighting

  1. Identify Emergency Lights: Locate all emergency lighting fixtures in the building.
  2. Access the Test Switch: Use the test switch to simulate a power failure.
  3. Verify Functionality: Check that all lights activate promptly and remain illuminated for the required duration.
  4. Inspect Backup Batteries: Ensure batteries are functioning and capable of supporting the system.
  5. Document Results: Record findings for compliance and schedule future maintenance.

Types of Emergency Lights

  • Battery-Powered Lights: Ideal for areas with unreliable power supply.
  • Main-Powered Lights: Common in commercial and high-traffic buildings.
graphic05 free img

Why Emergency Light Certificates Matter

  • Legal Requirement

Landlords and property managers are legally obligated to ensure emergency lighting systems are inspected and certified in compliance with fire safety regulations.

  • Insurance Compliance

Many insurance policies require valid emergency lighting certification to provide coverage during emergencies or power failures.

  • Safety Assurance

Properly functioning emergency lighting protects residents, staff, and visitors by guiding them safely during blackouts or fires.

  • System Integrity

Routine testing and certification help identify issues early, extending the life and reliability of emergency systems.

Frequently Asked Questions (FAQs)

  • It’s a formal inspection to ensure emergency lighting systems are operational, properly maintained, and compliant with BS 5266-1:2016 standards.
  • Monthly: Short-duration functional tests.
  • Annually: Full-duration discharge tests.
  • Engineers simulate a power failure, check light activation, inspect backup batteries, and document results for compliance.
  • It ensures safe evacuation during power failures, prevents injuries, and reduces panic in emergencies.
  • Non-compliance can result in fines, voided insurance policies, and legal liabilities.
  • Prices start at £69 for up to 3 lights, with additional lights costing £15 each.
  • Battery-Powered Lights: Ideal for areas with unreliable power.
  • Main-Powered Lights: Common in commercial buildings.

Yes, emergency lighting is required in multi-occupancy residential buildings and areas with shared access.

It’s the UK standard for emergency lighting, outlining installation, testing, and maintenance requirements.

Contact us via phone, email, or our website to schedule your test at a convenient time.